| Parameter | Specifications |
|---|---|
| Frequency Range | 0.1 -3,000 MHz |
| Frequency Resolution | 0.01 MHz |
| Frequency Accuracy | ± 2 ppm |
| Test Ports (single ended) | 4 (differential)/ 4 (single ended) |
| Test Ports (dual ended) | 8 (differential) |
| IF bandwidth | 100 Hz (range setting = 7) |
| Test Interface | SMA (female) |
| Impedance of Test Port | 50 Ω (single ended) 100 Ω (differential) |
| Test Port power output | -1.0 dBm |
| Max DC voltage at Test port (damage level) | 60 V |
| Sweep Speed | 0.3 msec/step (80 db noise floor) 3.4 msec/step (110 db noise floor) |
| RF Measurement Parameters | Differential-to-single ended return loss (SSD,x+/-,x) Differential-to-single ended cross-talk (SSD,y+/-,x) Differential-to-differential return loss (SDD,xx) Differential-to-differential cross-talk (SDD,yx). Differential to common mode return loss (TCL) (SCD,xx) Differential to common mode transmission (TCTL) (SCD,xx) Differential to common mode cross-talk (SCD,yx) |
| RF Measurement Parameters – Double Ended | Differential-to-single ended return loss and cross-talk. Differential-to-differential return loss and cross-talk. (near-end and far-end). Differential Insertion loss, differential to common-mode insertion loss |
| Measurement Floor – Cross-Talk (regular sweep mode) | 100 dB @ 0.1MHz 105 dB @ 1MHz 105 dB @ 100MHz 95 dB @ 600MHz 85 dB @ 1000MHz 50 dB @ 3000MHz |
| Measurement Floor- Return Loss (regular sweep mode) | 60 dB @ 0.1MHz 60 dB @ 1MHz 60 dB @ 100MHz 50 dB @ 600MHz 40 dB @ 1000MHz 15 dB @ 3000MHz |
| Dynamic Range transmission measurements (regular sweep mode) | 90 dB @ 0.1MHz 100 dB @ 1MHz 100 dB @ 100MHz 95 dB @ 600MHz 85 dB @ 1000MHz 50 dB @ 3000MHz |
| Accuracy – Transmission measurements (regular sweep mode) mid dynamic range measurements | ± 0.2 dB @ 0.1MHz ± 0.1 dB @ 1MHz ± 0.1 dB @ 100MHz ± 0.1 dB @ 600MHz ± 0.3 dB @ 1000MHz ± 0.5 dB @ 3000MHz |
| Accuracy – Reflection measurements mid dynamic range measurements | ± 0.4 dB |
| Directivity | 40 dB @ 0.1MHz 60 dB @ 1MHz 60 dB @ 100MHz 45 dB @ 600MHz 30 dB @ 1000MHz 25 dB @ 3000MHz |
| Tracking error | 0.05 dB (0.1 to 1000MHz) |
| Source Return Loss | 50 dB @ 1MHz 40 dB @ 100MHz 20 dB @ 1000 MHz |
| Insertion Loss Measurement range-dual ended | 80 dB @ 0.1MHz 80 dB @ 1MHz 70 dB@ 100 MHz 65 dB @ 1000 MHz 40 dB @ 3000 MHz |
| DC Measurement Parameters – Double Ended | End-to-end connectivity (wiremap) DC resistance pair-to-pair and wire-to-wire resistance unbalance |
| DC Resistance Measurement Range | 0 – 100 Ω (± 0.5 Ω) |
| DC Resistance measurement resolution | 0.1 Ω |
| File Format for S-parameter results | CSV and Touchstone (s8p, s16p) |
| Plots | frequency domain S-parameter (magnitude) time-domain impulse response (linear or dB) time-domain step response (impedance or dB) phase v/s frequency, real part v/s frequency, imaginary part v/s frequency ACRF, PSACRF for dual ended tests power sum measurements of selected combinations of S-parameters |
| size | 17.5cm (Depth) x 16.5cm (Width) x 5.5cm (Height) |
| File Format for S-parameter results | CSV and Touchstone (s8p, s16p) |
| weight | 1.0 kg |
| power supply | 5V DC adapter |
| Power consumption | 8 W |
| Battery Operation | 8 hours with full charge and 1 test/min |
| Connectivity | USB, 10/100/1000 Ethernet |
| Operating System | Linux |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -50 °C to +70 °C |
| Humidity | 90 % at 25 °C |
| Atmospheric pressure | 70.0 kPa to 106.7 kPa |