The AEM Networks 26.5 GHz Handheld VNA & TDR Adapter transforms the portable TestPro platform into a high-frequency, dual-mode test solution for laboratory, production and field environments. Operating from 1 MHz to 26.5 GHz, it brings advanced RF measurement capability closer to where cables, harnesses and interconnects are actually built, installed and maintained – reducing dependence on dedicated laboratory equipment.

Specifications

RF Performance Specifications

Specification Performance
Frequency Range 1 MHz - 26,500 MHz
Frequency Resolution 1 MHz
Frequency Accuracy ±2 ppm
Test Ports - Single-Ended 2
Test Interface SMA (Female)
Port Impedance 50 Ω
Test Port Output Power -1.0 dBm
Maximum DC at Test Port 60 V - damage level
IF Bandwidth 100 Hz - Range 7
TDR Resolution 13 ps / approximately 3.8 mm spatial
Sweep Speed 0.3 ms/step - -80 dB floor
3.4 ms/step - -110 dB floor

Measurement Floor - Cross-Talk Isolation

Frequency Measurement Floor
1 MHz 105 dB
1,000 MHz 85 dB
3,000 MHz 70 dB
16,000 MHz 50 dB
26,500 MHz 30 dB

Dynamic Range - Transmission

Frequency Dynamic Range
0.1 MHz 90 dB
1 MHz 100 dB
100 MHz 100 dB
1,000 MHz 85 dB
3,000 MHz 50 dB
26,500 MHz 50 dB

Measurement Floor - Return Loss

Frequency Measurement Floor
1 MHz 60 dB
1,000 MHz 40 dB
3,000 MHz 15 dB
16,000 MHz 15 dB
26,500 MHz 10 dB

Transmission Measurement Accuracy

Frequency Accuracy
1 MHz ±0.1 dB
100 MHz ±0.1 dB
600 MHz ±0.1 dB
1,000 MHz ±0.3 dB
6,000 MHz ±0.5 dB

Regular sweep mode, mid dynamic range.

Directivity

Frequency Directivity
0.1 MHz 40 dB
1 MHz 60 dB
100 MHz 60 dB
600 MHz 45 dB
1,000 MHz 30 dB
6,000 MHz 25 dB

Source Return Loss

Frequency Source Return Loss
1 MHz 50 dB
100 MHz 40 dB
1,000 MHz 20 dB

Insertion Loss Measurement Range

Frequency Measurement Range
0.1 MHz 80 dB
1 MHz 80 dB
100 MHz 70 dB
1,000 MHz 65 dB
6,000 MHz 40 dB

Display & Plot Types

  • S-parameter magnitude vs frequency
  • Time-domain impulse response – linear or dB
  • Time-domain step response – impedance or dB
  • Phase, real part and imaginary part vs frequency
  • Power sum of selected S-parameter combinations

Supported Standards

  • OPEN Alliance / BroadR-Reach
  • IEEE 802.3bw – 100BASE-T1
  • IEEE 802.3bp – 1000BASE-T1
  • IEEE 802.3ch

Platform & Interface Specifications

Specification Details
Platform AEM TestPro Handheld
Size - Unit 47.5 × 22 × 38 cm
Weight 1.0 kg - adapter only
Power Supply 5 V DC Adapter
Power Consumption 8 W
Battery Life 8 hours - 1 test/min
Connectivity USB, 10/100/1000 Ethernet
Operating System Linux
Operating Temperature 0 °C to 45 °C
Storage Temperature -50 °C to +70 °C
Humidity 90% RH @ 25 °C
Atmospheric Pressure 70.0 - 106.7 kPa
File Formats CSV, Touchstone (.s2p)
Software Software ThunderStorm GUI / CoreTest CLI
IP Access Remote view via Ethernet

New

Unlock Precision Testing with OTDR Adapters

Enhance your testing capabilities with our advanced OTDR test adapters. Designed to seamlessly integrate with both NSA and TestPro systems, these adapters are the perfect solution for accurate and reliable fiber optic testing.

  • Benefits: Seamless Compatibility: Works flawlessly with both NSA and TestPro platforms. 
  • Precision Testing: Achieve accurate and detailed results for your fiber optic networks. 
  • Easy Integration: Quick setup and hasslefree integration into your existing systems.
Secret Link